Country | United Kingdom | ||||||||
---|---|---|---|---|---|---|---|---|---|
Scope | Public Use | ||||||||
Legislation | Furniture & Furnishings Fire Safety Regulatios (amended 1988, 1989 y 1993) | Schedule 1 | Schedule 2 | Schedule 3 | Schedule 4 | Schedule 5 | Schedule 6 | Schedule 7 | Schedule 8 |
Standard Applied | BS 5852-1:1979 | BS 5852-2:1982 | BS 6807:1996 | ||||||
Application | Upholstered seating (armchairs, sofas, wing chairs, cribs, upholstered headboards, mattresses, pillows, puffs, cushions, etc.) | ||||||||
Specific Requirement |
| ||||||||
Scope | Public Use | ||||||||
Legislation | Regulatory Reform (Fire Safety) Order 2005 | ||||||||
Standard Applied | BS 7176:2008 | BS 7177:2008 | BS 6807:2006 | BS-EN 597-1/2:1995 | BS-EN 1021-1/2:2006 | BS 5852:1990 | |||
Application | Stores and offices (ISBN-13:978 1 85112 815 0) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use. Factories and warehouses (ISBN-13:978 1 85112 816 7) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use. | Sleeping accommodation (ISBN-13:978 1 85112 817 4) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture must comply with the premises of BS 7176. | Residential care installations (ISBN-13:978 1 85112 818 1) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture must comply with the premises of BS 7176. | Educational centres (ISBN-13:978 1 85112 810 8) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture must comply with the premises of BS 7176. | Small and medium sized public transit centres (ISBN-13:978 1 85112 820 4) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture must comply with the premises of BS 7176. | Large-scale public transit centres (ISBN-13:978 1 85112 821 1) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture must comply with the premises of BS 7176. | Theatres, cinemas and similar installations (ISBN-13:978 1 85112 822 8) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture must comply with the premises of BS 7176. | Open-air public transit centres (ISBN-13:978 1 85112 823 5) No specific requirements, but classification improves hazard evaluation. Health centres (ISBN-13:978 1 85112 824 2) Articles must comply with the specific code as in Health Technical Memorandum 05-03 Part C. | Public transport stations (ISBN-13:978 1 85112 824 2) In protected corridors and emergency exits the same premises must be complied with as in BS 7176 or for private use; In other cases, upholstered furniture fillings must comply with the premises of BS 7176. |
Specific Requirement |
|